The MarketPlace auction starts in 7 days.
Ref: 1738575

DATEX-OHMEDA Aestiva 5 Ref. 1738575


4,905.00

BrandDATEX-OHMEDA
ConditionRefurbished
ModelAestiva 5
WarrantyNot specified

Vaporizer not included.

External dimensions (configuration 2 vaporizers)
 Height: 53.4” (135.8 cm)
 Width: 29.5” (75 cm)
 Depth: 32.7” (83 cm)
 Weight: 300 lbs (136 kg)

Work Surface
 Height: 34,5 “(87,5 cm)
 Width: 18,5 “(47 cm)
 Depth: 12,4 “(31,5 cm)

Modes of Ventilation
 Volume Control Mode: With tidal volume compensation
 Pressure Mode: (optional)

Ventilation Parameters
 Tidal volume range: 45 to 1500 mL
 Incremental Settings: 45 to 100 mL (increments of 5 mL); 100 to 300 mL (increments of 10 mL); 300 to 1000 mL (increments of 25 mL); 1000 to 1500 mL (increments of 50 mL)
 Pressure (PInspired) Range: 5 to 50 cm H2O (increments of 1 cm H2O) (Pressure mode)
 Rate: 4 to 65 breaths per minute (increments of 1 breath per minute)
 Inspiratory/expiratory Ratio: 2:1 to 1:6 (increments of 0.5)
 Inspiratory Pause Adjust: 5% to 60% of inspiratory time (increments of 5%)

Positive End Expiratory Pressure (PEEP)
 Type: Integrated, electronically controlled
 Range: OFF, 4 to 30 cm H2O (increments of 1 cm H2O)

Ventilator Monitored Values
 Tidal volume: 5 to 1500 mL, 1 mL resolution
 Minute volume: 0 to 99.9 L/min, 0.1 L/min resolution
 Breathing rate: 0 to 65 breaths per minute, 1 breath per minute resolution
 Oxygen Percentage: 5% to 110%, 1% resolution
 Airway pressure: –9 to 99 cm H2O, 1 cm H2O resolution

Delivery/Monitoring Accuracy
 Volume delivery: > 200 mL = better than ±10% Set TV; 75 to 200 mL = better than ±20 mL; < 75 mL = better than ±15 mL
 Pressure (PInspired) Delivery Repeatability: ±2 cm H2O
 PEEP Delivery Repeatability: ±2 cm H2O
 Volume Monitoring: > 200 mL = better than ±10%; 75 to 200 mL = better than ±20 mL; < 75 mL = better than ±15 mL
 Pressure Monitoring: Better than ±2 cm H2O or ±5% of reading (whichever is greater)

Delivery
 Vaporizers: Tec 5, Tec 6 Plus or Tec 7
 Number of Positions: 2
 Mounting: Tool-free installation Selectatec manifold interlocks and isolates vaporizers

Ventilator Pneumatics
 Pressure Range at Inlet: 240 kPa to 700 kPa/35 psig to 100 psig
 Peak Gas Flow: 70 L/min + fresh gas flow
 Flow range: 2 to 70 L/min
 Flow Compensation Range: 200 mL/min to 15 L/min


You are interested in this vehicle ?
Don’t wait any longer, get in touch with the company Medika MCN Tecnologia Medicinal Lda to know more right now !
4,905.00

Trusted Seller
Sold: 94
Sold with Escrow: 23
Registered: 28/05/2019
Shipping from: Portugal
Rating: (9 verified reviews)
  Safety advice
BrandDATEX-OHMEDA
ConditionRefurbished
ModelAestiva 5
WarrantyNot specified

Vaporizer not included.

External dimensions (configuration 2 vaporizers)
 Height: 53.4” (135.8 cm)
 Width: 29.5” (75 cm)
 Depth: 32.7” (83 cm)
 Weight: 300 lbs (136 kg)

Work Surface
 Height: 34,5 “(87,5 cm)
 Width: 18,5 “(47 cm)
 Depth: 12,4 “(31,5 cm)

Modes of Ventilation
 Volume Control Mode: With tidal volume compensation
 Pressure Mode: (optional)

Ventilation Parameters
 Tidal volume range: 45 to 1500 mL
 Incremental Settings: 45 to 100 mL (increments of 5 mL); 100 to 300 mL (increments of 10 mL); 300 to 1000 mL (increments of 25 mL); 1000 to 1500 mL (increments of 50 mL)
 Pressure (PInspired) Range: 5 to 50 cm H2O (increments of 1 cm H2O) (Pressure mode)
 Rate: 4 to 65 breaths per minute (increments of 1 breath per minute)
 Inspiratory/expiratory Ratio: 2:1 to 1:6 (increments of 0.5)
 Inspiratory Pause Adjust: 5% to 60% of inspiratory time (increments of 5%)

Positive End Expiratory Pressure (PEEP)
 Type: Integrated, electronically controlled
 Range: OFF, 4 to 30 cm H2O (increments of 1 cm H2O)

Ventilator Monitored Values
 Tidal volume: 5 to 1500 mL, 1 mL resolution
 Minute volume: 0 to 99.9 L/min, 0.1 L/min resolution
 Breathing rate: 0 to 65 breaths per minute, 1 breath per minute resolution
 Oxygen Percentage: 5% to 110%, 1% resolution
 Airway pressure: –9 to 99 cm H2O, 1 cm H2O resolution

Delivery/Monitoring Accuracy
 Volume delivery: > 200 mL = better than ±10% Set TV; 75 to 200 mL = better than ±20 mL; < 75 mL = better than ±15 mL
 Pressure (PInspired) Delivery Repeatability: ±2 cm H2O
 PEEP Delivery Repeatability: ±2 cm H2O
 Volume Monitoring: > 200 mL = better than ±10%; 75 to 200 mL = better than ±20 mL; < 75 mL = better than ±15 mL
 Pressure Monitoring: Better than ±2 cm H2O or ±5% of reading (whichever is greater)

Delivery
 Vaporizers: Tec 5, Tec 6 Plus or Tec 7
 Number of Positions: 2
 Mounting: Tool-free installation Selectatec manifold interlocks and isolates vaporizers

Ventilator Pneumatics
 Pressure Range at Inlet: 240 kPa to 700 kPa/35 psig to 100 psig
 Peak Gas Flow: 70 L/min + fresh gas flow
 Flow range: 2 to 70 L/min
 Flow Compensation Range: 200 mL/min to 15 L/min


Sign in