1
Negotiate Terms with Seller
Discuss and agree upon the equipment's condition, configuration, and pricing with the seller before proceeding.
Brand | DRAGER |
Condition | Refurbished |
Model | Evita 2 Dura |
Warranty | Not specified |
The Evita 2 dura provides patient and ventilator-related monitoring with user interaction reduced to a minimum. The high-resolution full-color screen displays comprehensive information on a patient’s status, always showing two ventilation curves and six monitored values, and the screen configuration can be customized to show the most important values for a particular ICU.
Higher functional residual capacity.
Utilizes AutoFlow technology.
Accommodates neonatal, pediatric or adult patients.
First-Class ventilator performance.
Modular upgradeability.
Can be used for both conventional and
non-invasive ventilation.
High-resolution full-color display.
Customizable display/monitoring.
Rotary knob and soft keys for ease of use.
Programmable weaning.
Drager Evita 2 Dura Specifications
Spontaneous breathing strategy. Spontaneous breathing reduces the risk of atelectasis and improves the ventilation/perfusion ratio by maintaining a higher functional residual capacity.
The right mode for every patient. The wide range of patients covered also reduces the amount of staff training required and ensures greater flexibility in the use of resources.
Two-in-one ventilation. Mask ventilation can assist the weaning process by reducing the reintubation rate or even preventing intubation in the first place.
Everything in view. The high-resolution full-color screen displays comprehensive information on a patient’s status, always showing two ventilation curves and six monitored values, and the screen configuration can be customized to show the most important values for a particular ICU.
One knob, simplified settings. The rotary knob plays a key role. The active setting parameters are visible at a glance and changes can be made by the well-established “select-adjust confirm” principle.
Ventilation at a glance. The principle of only showing the necessary parameters reduces the complexity of everyday monitoring.
Simpler and speedier standard procedures. Contains numerous functions to speed up and simplify routine procedures. Start-up settings can be configured to specific ICU practices.
Dimensions
Height: 11.4 In (290 cm)
Width: 20.9 In (530 cm)
Depth: 17.7 In (450 cm)
Weight: Approx. 27 kg (60 lbs)
Diagonal Screen size: 6.5” TFT LCD color Display
Ventilation Settings
Ventilation mode: IPPV, IPPVAssist (CMV, CMVAssist) SIMV, SIMVASB (SIMV, SIMV/Psupp) MMV, MMVASB (MMV, MMV/Psupp) BIPAP1), BIPAP1)ASB, BIPAP1)Assist (PCV+, PCV+/Psupp, PCV+Assist) CPAP, CPAPASB (CPAP, CPAP/Psupp) APRV (optional) ILV (optional)
Enhancements: AutoFlow™ – Automatic adaptation of inspiratory flow in volume controlled modes ATC™ – Automatic Tube Compensation (optional) IV – Mask Ventilation (optional)
Ventilation frequency (f): 0 to 100 /min, 0 to150 /min (Neonatal)
Inspiration time (Tinsp): 0.1 to 10 s
Tidal volume (VT) (BTPS): 0.1 to 2.0 L (Adult) 0.02 to 0.3 L (Pediatric) 0.003 to 0.1 L (Neonatal)
Inspiratory flow: 6 to 120 L/min (Adult) 6 to 30 L/min (Pediatric and Neonatal)
Inspiratory pressure: 0 to 80 mbar (cmH2O) PEEP / intermittent PEEP: 0 to 35 mbar (cmH2O)
Pressureassist (PASB) (Psupp): 0 to 80 mbar (cmH2O)
Rise time for inspiratory pressure: 0 to 2 s
O2 concentration: 21 to 100 Vol.%
Multi-sense Trigger Criteria: Internal automatic pressure trigger, Flow, Volume (Flow adjustable 0.3 to 15 L/min)
Measured Values Displayed
IAirway pressure: Peak pressure, plateau pressure, mean pressure, PEEP, min. pressure (0 to 99 mbar/cmH2O)
Minute volume (MV), (BTPS): MV, MVspont, MVleak (0 to 99 L/min)
Tidal volume (VT), (BTPS): Inspired VT, expired VT, VTASB (VTPS) (0 to 3999 mL)
Breathing frequency (f): ftotal, fspon, fmand. (0 to 300/bpm)
O2 concentration: (FiO2) Inspired O2 concentration (15 to 100 Vol.%)
Lung mechanics: Resistance ((0.0 to 600 mbar/L/s)(cmH2O/L/s) Compliance ((0.0 to 300 mL/mbar)(mL/cmH2O)
Breathing gas temperature: 18°to 51°C
Waveforms: Airway pressure-time, flow-time, volume-time, …
Trends (optional): FiO2, MV, VT, f, PEEPi, R, C, etCO2, …
Loops (optional): Paw-V, V-Flow, Flow-Paw, …
Capnography (etCO2) (optional): 0 to 100 mmHg
CO2 production (VCO2): 0 to 999 mL/min, STPD
Serial dead space Vds: 0 to 999 mL, BTPS
Alarms / Monitoring
Airway pressure: High/Low
Expired minute volume: High/Low
Tidal volume: High
Tidal volume (VT) (BTPS): 0.1 to 2.0 L (Adult) 0.02 to 0.3 L (Pediatric) 0.003 to 0.1 L (Neonatal)
Inspiratory flow: 6 to 120 L/min (Adult) 6 to 30 L/min (Pediatric and Neonatal)
Apnea alarm time: 5 to 60 s
Spontaneous breath frequency: High
Inspired O2 concentration: High/Low
Breathing gas temperature: High
SpO2 pulse (optional): High/Low
etCO2 (optional): High/Low
Performance Data
Max. flow for pressure support and spontaneous breathing: 180 L/min (adult), 60 L/min (pediatric)
Valve response time: ≤ 5 ms
Control principle: Time cycled, volume constant, pressure-controlled
Safety relief valve: 100 bar (cmH2O)
Leakage compensation
Hose system compensation
An outlet for pneumatic nebulizer
Brand | DRAGER |
Condition | Refurbished |
Model | Evita 2 Dura |
Warranty | Not specified |
The Evita 2 dura provides patient and ventilator-related monitoring with user interaction reduced to a minimum. The high-resolution full-color screen displays comprehensive information on a patient’s status, always showing two ventilation curves and six monitored values, and the screen configuration can be customized to show the most important values for a particular ICU.
Higher functional residual capacity.
Utilizes AutoFlow technology.
Accommodates neonatal, pediatric or adult patients.
First-Class ventilator performance.
Modular upgradeability.
Can be used for both conventional and
non-invasive ventilation.
High-resolution full-color display.
Customizable display/monitoring.
Rotary knob and soft keys for ease of use.
Programmable weaning.
Drager Evita 2 Dura Specifications
Spontaneous breathing strategy. Spontaneous breathing reduces the risk of atelectasis and improves the ventilation/perfusion ratio by maintaining a higher functional residual capacity.
The right mode for every patient. The wide range of patients covered also reduces the amount of staff training required and ensures greater flexibility in the use of resources.
Two-in-one ventilation. Mask ventilation can assist the weaning process by reducing the reintubation rate or even preventing intubation in the first place.
Everything in view. The high-resolution full-color screen displays comprehensive information on a patient’s status, always showing two ventilation curves and six monitored values, and the screen configuration can be customized to show the most important values for a particular ICU.
One knob, simplified settings. The rotary knob plays a key role. The active setting parameters are visible at a glance and changes can be made by the well-established “select-adjust confirm” principle.
Ventilation at a glance. The principle of only showing the necessary parameters reduces the complexity of everyday monitoring.
Simpler and speedier standard procedures. Contains numerous functions to speed up and simplify routine procedures. Start-up settings can be configured to specific ICU practices.
Dimensions
Height: 11.4 In (290 cm)
Width: 20.9 In (530 cm)
Depth: 17.7 In (450 cm)
Weight: Approx. 27 kg (60 lbs)
Diagonal Screen size: 6.5” TFT LCD color Display
Ventilation Settings
Ventilation mode: IPPV, IPPVAssist (CMV, CMVAssist) SIMV, SIMVASB (SIMV, SIMV/Psupp) MMV, MMVASB (MMV, MMV/Psupp) BIPAP1), BIPAP1)ASB, BIPAP1)Assist (PCV+, PCV+/Psupp, PCV+Assist) CPAP, CPAPASB (CPAP, CPAP/Psupp) APRV (optional) ILV (optional)
Enhancements: AutoFlow™ – Automatic adaptation of inspiratory flow in volume controlled modes ATC™ – Automatic Tube Compensation (optional) IV – Mask Ventilation (optional)
Ventilation frequency (f): 0 to 100 /min, 0 to150 /min (Neonatal)
Inspiration time (Tinsp): 0.1 to 10 s
Tidal volume (VT) (BTPS): 0.1 to 2.0 L (Adult) 0.02 to 0.3 L (Pediatric) 0.003 to 0.1 L (Neonatal)
Inspiratory flow: 6 to 120 L/min (Adult) 6 to 30 L/min (Pediatric and Neonatal)
Inspiratory pressure: 0 to 80 mbar (cmH2O) PEEP / intermittent PEEP: 0 to 35 mbar (cmH2O)
Pressureassist (PASB) (Psupp): 0 to 80 mbar (cmH2O)
Rise time for inspiratory pressure: 0 to 2 s
O2 concentration: 21 to 100 Vol.%
Multi-sense Trigger Criteria: Internal automatic pressure trigger, Flow, Volume (Flow adjustable 0.3 to 15 L/min)
Measured Values Displayed
IAirway pressure: Peak pressure, plateau pressure, mean pressure, PEEP, min. pressure (0 to 99 mbar/cmH2O)
Minute volume (MV), (BTPS): MV, MVspont, MVleak (0 to 99 L/min)
Tidal volume (VT), (BTPS): Inspired VT, expired VT, VTASB (VTPS) (0 to 3999 mL)
Breathing frequency (f): ftotal, fspon, fmand. (0 to 300/bpm)
O2 concentration: (FiO2) Inspired O2 concentration (15 to 100 Vol.%)
Lung mechanics: Resistance ((0.0 to 600 mbar/L/s)(cmH2O/L/s) Compliance ((0.0 to 300 mL/mbar)(mL/cmH2O)
Breathing gas temperature: 18°to 51°C
Waveforms: Airway pressure-time, flow-time, volume-time, …
Trends (optional): FiO2, MV, VT, f, PEEPi, R, C, etCO2, …
Loops (optional): Paw-V, V-Flow, Flow-Paw, …
Capnography (etCO2) (optional): 0 to 100 mmHg
CO2 production (VCO2): 0 to 999 mL/min, STPD
Serial dead space Vds: 0 to 999 mL, BTPS
Alarms / Monitoring
Airway pressure: High/Low
Expired minute volume: High/Low
Tidal volume: High
Tidal volume (VT) (BTPS): 0.1 to 2.0 L (Adult) 0.02 to 0.3 L (Pediatric) 0.003 to 0.1 L (Neonatal)
Inspiratory flow: 6 to 120 L/min (Adult) 6 to 30 L/min (Pediatric and Neonatal)
Apnea alarm time: 5 to 60 s
Spontaneous breath frequency: High
Inspired O2 concentration: High/Low
Breathing gas temperature: High
SpO2 pulse (optional): High/Low
etCO2 (optional): High/Low
Performance Data
Max. flow for pressure support and spontaneous breathing: 180 L/min (adult), 60 L/min (pediatric)
Valve response time: ≤ 5 ms
Control principle: Time cycled, volume constant, pressure-controlled
Safety relief valve: 100 bar (cmH2O)
Leakage compensation
Hose system compensation
An outlet for pneumatic nebulizer