1
Negotiate Terms with Seller
Discuss and agree upon the equipment's condition, configuration, and pricing with the seller before proceeding.
Brand | ERBE |
Condition | Certified Refurbished |
Model | ICC 200 |
Warranty | Not specified |
ENDO CUT™ for use with snare wires and sphincterotomes
Power on Demand – As much as necessary, as little as possible
Forced Coag™
Soft Coag™
Expandable for Argon use
ERBE Erbotom ICC 200 Specifications
Dimensions
Width: 280mm
Height:152 mm
Depth: 368 mm
Weight: 8 kg
Operating Mode
Intermittent operation: ON time 25 % (e.g. activated for 10 sec. / deactivated for 30 sec.)
Environmental conditions for shipping and storage of the unit
Temperature: -40°C to + 70°C
Air Humidity, relative: 10% to 95%
Environmental conditions for the operation of the unit
Temperature: +10°C to + 40°C
Air Humidity, relative: 130% to 75%, noncondensing
Power Conditions
Rated power voltage: 240 V / 230 V / 115 V / 110 V / 100 V ± 10 %
Rated power frequency: 50 / 60 Hz
Power Current: 3.0 A at 230 – 240 V / 6.0 A at 100 – 115 V
Power consumption in Standby mode: 25 Watts
Power consumption at max. HF power: 450 Watts 690 VA
Current consumption in Standby mode: 150 mA at 230 – 240 V / 300 mA at 100 – 115 V
Potential equalization terminal: Yes
Power Fuse: 2 slow burns, 4 A at 230 – 240 V / 8 A at 100 – 115 V
Energy
Max. energy output ( at rated ohms) (Systems) Up to 250 Watt 200
Max voltage, VP-p (Systems) Software controlled
Max. energy output ( at rated ohms) (Systems) Up to 150 Watt 120
Max voltage, VP-p (Systems) 380 soft, 5,600 spray
Bipolar (Systems) Coagulate
Max. energy output ( at rated ohms) (Systems) Up to 150 Watt 120
Max voltage, VP-p (Systems) 380
Brand | ERBE |
Condition | Certified Refurbished |
Model | ICC 200 |
Warranty | Not specified |
ENDO CUT™ for use with snare wires and sphincterotomes
Power on Demand – As much as necessary, as little as possible
Forced Coag™
Soft Coag™
Expandable for Argon use
ERBE Erbotom ICC 200 Specifications
Dimensions
Width: 280mm
Height:152 mm
Depth: 368 mm
Weight: 8 kg
Operating Mode
Intermittent operation: ON time 25 % (e.g. activated for 10 sec. / deactivated for 30 sec.)
Environmental conditions for shipping and storage of the unit
Temperature: -40°C to + 70°C
Air Humidity, relative: 10% to 95%
Environmental conditions for the operation of the unit
Temperature: +10°C to + 40°C
Air Humidity, relative: 130% to 75%, noncondensing
Power Conditions
Rated power voltage: 240 V / 230 V / 115 V / 110 V / 100 V ± 10 %
Rated power frequency: 50 / 60 Hz
Power Current: 3.0 A at 230 – 240 V / 6.0 A at 100 – 115 V
Power consumption in Standby mode: 25 Watts
Power consumption at max. HF power: 450 Watts 690 VA
Current consumption in Standby mode: 150 mA at 230 – 240 V / 300 mA at 100 – 115 V
Potential equalization terminal: Yes
Power Fuse: 2 slow burns, 4 A at 230 – 240 V / 8 A at 100 – 115 V
Energy
Max. energy output ( at rated ohms) (Systems) Up to 250 Watt 200
Max voltage, VP-p (Systems) Software controlled
Max. energy output ( at rated ohms) (Systems) Up to 150 Watt 120
Max voltage, VP-p (Systems) 380 soft, 5,600 spray
Bipolar (Systems) Coagulate
Max. energy output ( at rated ohms) (Systems) Up to 150 Watt 120
Max voltage, VP-p (Systems) 380
Write us an email!
We will call you back soon!
Contact us