1
Negotiate Terms with Seller
Discuss and agree upon the equipment's condition, configuration, and pricing with the seller before proceeding.
Brand | ERBE |
Condition | Certified Refurbished |
Model | VIO200D |
Warranty | Not specified |
Automatical dosage of power.
New and improved CUT and COAG functions.
Modular software and hardware.
Widest choice of socket modules and functions.
ReMode – new activation via „remote control straight from the sterile field.
The VIO 200 D – the master control unit for other modules of the VIO electrosurgical system, e.g. the APC
2.ERBE Vio 200 D Specifications
Dimensions
Width: 16.14 in (410 mm)
Height:6.5in (165mm)
Depth: 14.96in (380mm)
Weight: 9.5kg (20.94)
Operating Mode
Intermittent Operation: ON time 25% (e.g. activated for 10 sec. / deactivated for 30 sec.)
Ambient conditions for transport and storage of unit
Temperature: -40 °C to +70 °C
Relative Humidity: 10 % – 95 %
Ambient conditions for operating of the unit
Temperature: +10°C to +40°C
Relative Humidity: 15% – 80%, non-condensing
Power Output
Maximum cut power: 200 watts at 500 Ohm
Maximum COAG power: up to 200 watts
NE safety system: NESSY
Frequency: 350 kHz
Power Connection
Line voltage 100 V – 120 V / 220 V – 240 V ± 10 %
Power frequency 50 / 60 Hz
Line current max. 8 A / 4 A
Power consumption in standby mode 40 watts
Power consumption at max. HF power 500 watts / 920 VA
Potential equalization connection Yes
Power fuse T 8 A / T 4 A
Brand | ERBE |
Condition | Certified Refurbished |
Model | VIO200D |
Warranty | Not specified |
Automatical dosage of power.
New and improved CUT and COAG functions.
Modular software and hardware.
Widest choice of socket modules and functions.
ReMode – new activation via „remote control straight from the sterile field.
The VIO 200 D – the master control unit for other modules of the VIO electrosurgical system, e.g. the APC
2.ERBE Vio 200 D Specifications
Dimensions
Width: 16.14 in (410 mm)
Height:6.5in (165mm)
Depth: 14.96in (380mm)
Weight: 9.5kg (20.94)
Operating Mode
Intermittent Operation: ON time 25% (e.g. activated for 10 sec. / deactivated for 30 sec.)
Ambient conditions for transport and storage of unit
Temperature: -40 °C to +70 °C
Relative Humidity: 10 % – 95 %
Ambient conditions for operating of the unit
Temperature: +10°C to +40°C
Relative Humidity: 15% – 80%, non-condensing
Power Output
Maximum cut power: 200 watts at 500 Ohm
Maximum COAG power: up to 200 watts
NE safety system: NESSY
Frequency: 350 kHz
Power Connection
Line voltage 100 V – 120 V / 220 V – 240 V ± 10 %
Power frequency 50 / 60 Hz
Line current max. 8 A / 4 A
Power consumption in standby mode 40 watts
Power consumption at max. HF power 500 watts / 920 VA
Potential equalization connection Yes
Power fuse T 8 A / T 4 A
Write us an email!