Brand | GE |
Condition | Certified Refurbished |
Model | Dash 3000 |
Warranty | Not specified |
Built-in wireless LAN provides seamless network connectivity
Exclusive two-way communication allows clinicians to receive alarms and check-in on other patients during transport
DASH port docking stations provide a one-step connection to the Unity network and AC power
Eliminates need to connect and disconnect leads
Patient Data Transfer (PDT) ensures seamless patient record as a patient moves through the hospital
Connectivity to high-security Solar and TRAM monitors creates a convenient single-source, the hospital-wide monitoring solution
DASH 3000 is the only full-featured patient monitor with DINAMAP technology built-in
The system consistently produces the most accurate, reliable NIBP determinations available in a bedside monitor
Stepped deflation with patented peak matching technology helps ride through artifact
Ideally suited for ICU, PICU and hypersensitive patients
The durable design of DASH 3000 creates a dependable solution for demanding transport applications, including air transport
The compact system integrates a printer, transformer and power supply providing exceptional capability in a highly maneuverable package
GE Dash 3000 Specifications:
Dimensions
Height: 26 cm.
Depth: 20 cm.
Width: 28 cm
Weight: 5.5 kg
Display
Size: 22 cm (diagonal).
Type: active-matrix color TFT.
Resolution: 640 x 480 pixels.
A number of traces: 6 maximum.
Number of seconds/trace: 4.9 at 25 mm/sec.
Sweep Speed: 6.25, 12.5, 25 mm/sec (with erase bar).
Information window: displays non-real-time information without obstructing the display of real-time information.
Display organization: prioritized by parameter.
Controls
Trim Knob® control.
Five hard keys: Silence Alarm, Graph Go/Stop, NIBP Go/Stop, function (zero all) and Power On/Off.
Alarms
Categories: patient status and system status.
Priority: 4-levels crisis, warning, advisory, message.
Notification: audible and visual.
Settings: default or user-defined.
Silencing: 1 minute, current alarm only.
Pause: 5 minutes in adult ICU mode, 3 minutes in Neonatal ICU mode, and 5, 15, minutes or permanent pause in OR mode.
ECG
Standard leads available: I, II, III, V, aVR, aVL, and aVF.
Leads analyzed simultaneously: I, II, III and V (multi-lead).
Lead fail: identifies failed lead.
Alarms: user-selectable upper and lower heart rate limits.
Respiration
Measurement technique: impedance variation detection. Range respiration rate: 0-200 breaths per minute. User-selectable upper and lower respiration rate limits, and user-selectable apnea limit.
Temperature
Number of channels: 2.
Resolution: ±0.1°C.
Alarms: user-selectable upper and lower limits for T1, T2.
Invasive Blood Pressure
A number of channels: 2.
Range: -25mmHg to 300mmHg.
Alarms: user-selectable upper and lower limits for systolic, diastolic, and mean pressures.
NIBP
Measurement technique: oscillometric.
Displayed parameters: systolic, diastolic, and mean pressures, time of the last measurement.
Measurement modes: manual, auto, and stat in Adult ICU and OR modes, manual and auto in neonatal mode.
Systolic range: 30-275 mmHg adult, 30-235 mmHg pediatric, 30-135 mmHg neonate.
Diastolic range: 10-220mmHg adult, 10-220mmHg pediatric, 10-110 mmHg neonate.
Pulse Oximetry
Parameters monitored: SpO2 and peripheral pulse rate.
SpO2 range: 50-100%.
PPR range: 30-300 beats per minute.
SpO2 accuracy: ±2%, 70 – 100% SpO2, ±3% (50-69% SpO2).
PPR Accuracy: ±3 beats per minute.
Brand | GE |
Condition | Certified Refurbished |
Model | Dash 3000 |
Warranty | Not specified |
Built-in wireless LAN provides seamless network connectivity
Exclusive two-way communication allows clinicians to receive alarms and check-in on other patients during transport
DASH port docking stations provide a one-step connection to the Unity network and AC power
Eliminates need to connect and disconnect leads
Patient Data Transfer (PDT) ensures seamless patient record as a patient moves through the hospital
Connectivity to high-security Solar and TRAM monitors creates a convenient single-source, the hospital-wide monitoring solution
DASH 3000 is the only full-featured patient monitor with DINAMAP technology built-in
The system consistently produces the most accurate, reliable NIBP determinations available in a bedside monitor
Stepped deflation with patented peak matching technology helps ride through artifact
Ideally suited for ICU, PICU and hypersensitive patients
The durable design of DASH 3000 creates a dependable solution for demanding transport applications, including air transport
The compact system integrates a printer, transformer and power supply providing exceptional capability in a highly maneuverable package
GE Dash 3000 Specifications:
Dimensions
Height: 26 cm.
Depth: 20 cm.
Width: 28 cm
Weight: 5.5 kg
Display
Size: 22 cm (diagonal).
Type: active-matrix color TFT.
Resolution: 640 x 480 pixels.
A number of traces: 6 maximum.
Number of seconds/trace: 4.9 at 25 mm/sec.
Sweep Speed: 6.25, 12.5, 25 mm/sec (with erase bar).
Information window: displays non-real-time information without obstructing the display of real-time information.
Display organization: prioritized by parameter.
Controls
Trim Knob® control.
Five hard keys: Silence Alarm, Graph Go/Stop, NIBP Go/Stop, function (zero all) and Power On/Off.
Alarms
Categories: patient status and system status.
Priority: 4-levels crisis, warning, advisory, message.
Notification: audible and visual.
Settings: default or user-defined.
Silencing: 1 minute, current alarm only.
Pause: 5 minutes in adult ICU mode, 3 minutes in Neonatal ICU mode, and 5, 15, minutes or permanent pause in OR mode.
ECG
Standard leads available: I, II, III, V, aVR, aVL, and aVF.
Leads analyzed simultaneously: I, II, III and V (multi-lead).
Lead fail: identifies failed lead.
Alarms: user-selectable upper and lower heart rate limits.
Respiration
Measurement technique: impedance variation detection. Range respiration rate: 0-200 breaths per minute. User-selectable upper and lower respiration rate limits, and user-selectable apnea limit.
Temperature
Number of channels: 2.
Resolution: ±0.1°C.
Alarms: user-selectable upper and lower limits for T1, T2.
Invasive Blood Pressure
A number of channels: 2.
Range: -25mmHg to 300mmHg.
Alarms: user-selectable upper and lower limits for systolic, diastolic, and mean pressures.
NIBP
Measurement technique: oscillometric.
Displayed parameters: systolic, diastolic, and mean pressures, time of the last measurement.
Measurement modes: manual, auto, and stat in Adult ICU and OR modes, manual and auto in neonatal mode.
Systolic range: 30-275 mmHg adult, 30-235 mmHg pediatric, 30-135 mmHg neonate.
Diastolic range: 10-220mmHg adult, 10-220mmHg pediatric, 10-110 mmHg neonate.
Pulse Oximetry
Parameters monitored: SpO2 and peripheral pulse rate.
SpO2 range: 50-100%.
PPR range: 30-300 beats per minute.
SpO2 accuracy: ±2%, 70 – 100% SpO2, ±3% (50-69% SpO2).
PPR Accuracy: ±3 beats per minute.