The MarketPlace auction starts in 7 days.
Ref: 1937832

MAQUET Servo-S Ref. 1937832


2,725.00

BrandMAQUET
ModelServo-S
WarrantyNot specified

SIEMENS MAQUET SERVO-S

ICU VENTILATOR

Good Condition

TESTED FUNCTIONAL

Siemens Maquet SERVO-s Features

The Getinge Maquet Servo-s ventilator features a wide range of ventilation modes that can be tailored to specific clinical situations. The Servo-s has a large intuitive user-interface that provides valuable decision-support information. This Maquet ventilator has been designed for both shelf mounting and in-hospital transport with a mobile cart. It supports invasive and non-invasive ventilation with leakage compensation for non-invasive ventilation modes for all patient types.

  • Invasive and non-invasive ventilation with leakage compensation.
  • User friendly user-interface.
  • Rotary dial and direct access knobs for navigation.
  • Designed for shelf mounting or intrahospital transport with a mobile cart.
  • Quick inspiratory flow controller allows for reduced work of patient breathing.

Parameter Settings

  • Inspiratory tidal volume (ml): 100–2000
  • Inspiratory minute volume (l/min): 0.5–60
  • Apnea, time to alarm (s): 15–45
  • PC/PS above PEEP (cmH2O): 0–(120 – PEEP)
  • PC/PS above PEEP in NIV (cmH2O): 0–(62 – PEEP)
  • PEEP (cmH2O): 0–50
  • PEEP in NIV (cmH2O): 2–20
  • CMV frequency (breaths/min): 4–100
  • SIMV frequency (breaths/min): 1–60
  • Breath cycle time, SIMV (s): 1–15
  • PHigh (cmH20): (PEEP + 1)–50
  • THigh (s): 0.2–30
  • TPEEP (s): 0.1–10
  • O2 concentration (%): 21–100
  • I:E ratio: 1:10–4:1
  • TInsp (s): 0.1–5
  • TPause (% of breath cycle time): 0–30
  • Flow trigger sensitivity level: 0–10
  • Press. trigg sensitivity (cmH2O): -20–0
  • Insp. rise time (% of breath cycle time): 0–20
  • Insp. rise time (s): 0–0.4
  • End inspiration (% of peak flow): 1–70
  • End inspiration in NIV (% of peak flow): 10–70
  • Oxygen Breaths: 100% for 1 minute
  • Start Breath: Initiation of 1 breath (In SIMV mode initiation of 1 mandatory breath)
  • Pause Hold: Insp. or exp (0–30 seconds)

Backup Parameter Settings

  • Inspiratory Tidal Volume (ml): 100–2000
  • PC Above PEEP (cmH2O): 5–(120 – PEEP)
  • PC above PEEP in NIV (cmH2 O): 5–(62 – PEEP)
  • CMV frequency (breaths/min): 4–100
  • I:E ratio: 1:10–4:1
  • TInsp (s): 0.1–5

Controlled Invasive Ventilation

  • PC (Pressure Control)
  • VC (Volume Control)
  • PRVC (Pressure Regulated Volume Control)
  • Can be configured with alternative flow patterns: VC with flow ada ptation; VC without flow adaptation; VC with decelerating flow

Supported Invasive Ventilation

  • PS/CPAP (Pressure Support / Continuous Positive Airway Pressure)

Combined Invasive Ventilation

  • SIMV (PC) + PS (Synchronized Intermittent Mandatory Ventilation)
  • SIMV (VC) + PS
  • SIMV (PRVC) + PS
  • Bi-Vent/APRV (Airway Pressure Release Ventilation)

Non Invasive Ventilation

  • Leakage Compensation Level: Inspiratory, up to 200 l/min; Expiratory, up to 65 l/ min
  • Leakage Overrange Detection: Automatic
  • Disconnect Detection: Automatic
  • Disconnect flow: Low; High; Disabled; Configurable 7.5 l/min; 40 l/min;
  • Deactivates disconnect detection
  • Connect Detection: Manual, or automatic via bias flow

Pre-owned, was removed from hospital in working condition.

International Shipping

We do our best to ship items the same day the payment has cleared, in some instances we are unable to. All items will be shipped within 1-4 working days

Returns

If you are not 100% satisfied with your purchase, we have a 14-day money back guarantee policy. Excluding Items sold as-is / for parts only. Reimbursement for returns will be paid after the purchased item is returned. Free returns apply to damaged, broken and items not as described! Buyer is responsible for return shipping on items purchased accidentally or items no longer wanted/needed etc.

We ship worldwide !

Please feel free to contact us for any question!


You are interested in this vehicle ?
Don’t wait any longer, get in touch with the company East West Medical to know more right now !
2,725.00

Trusted Seller
Sold: 490
Sold with Escrow: 116
Registered: 01/01/1970
Shipping from: France
Rating: (0 verified reviews)
  Safety advice
BrandMAQUET
ModelServo-S
WarrantyNot specified

SIEMENS MAQUET SERVO-S

ICU VENTILATOR

Good Condition

TESTED FUNCTIONAL

Siemens Maquet SERVO-s Features

The Getinge Maquet Servo-s ventilator features a wide range of ventilation modes that can be tailored to specific clinical situations. The Servo-s has a large intuitive user-interface that provides valuable decision-support information. This Maquet ventilator has been designed for both shelf mounting and in-hospital transport with a mobile cart. It supports invasive and non-invasive ventilation with leakage compensation for non-invasive ventilation modes for all patient types.

  • Invasive and non-invasive ventilation with leakage compensation.
  • User friendly user-interface.
  • Rotary dial and direct access knobs for navigation.
  • Designed for shelf mounting or intrahospital transport with a mobile cart.
  • Quick inspiratory flow controller allows for reduced work of patient breathing.

Parameter Settings

  • Inspiratory tidal volume (ml): 100–2000
  • Inspiratory minute volume (l/min): 0.5–60
  • Apnea, time to alarm (s): 15–45
  • PC/PS above PEEP (cmH2O): 0–(120 – PEEP)
  • PC/PS above PEEP in NIV (cmH2O): 0–(62 – PEEP)
  • PEEP (cmH2O): 0–50
  • PEEP in NIV (cmH2O): 2–20
  • CMV frequency (breaths/min): 4–100
  • SIMV frequency (breaths/min): 1–60
  • Breath cycle time, SIMV (s): 1–15
  • PHigh (cmH20): (PEEP + 1)–50
  • THigh (s): 0.2–30
  • TPEEP (s): 0.1–10
  • O2 concentration (%): 21–100
  • I:E ratio: 1:10–4:1
  • TInsp (s): 0.1–5
  • TPause (% of breath cycle time): 0–30
  • Flow trigger sensitivity level: 0–10
  • Press. trigg sensitivity (cmH2O): -20–0
  • Insp. rise time (% of breath cycle time): 0–20
  • Insp. rise time (s): 0–0.4
  • End inspiration (% of peak flow): 1–70
  • End inspiration in NIV (% of peak flow): 10–70
  • Oxygen Breaths: 100% for 1 minute
  • Start Breath: Initiation of 1 breath (In SIMV mode initiation of 1 mandatory breath)
  • Pause Hold: Insp. or exp (0–30 seconds)

Backup Parameter Settings

  • Inspiratory Tidal Volume (ml): 100–2000
  • PC Above PEEP (cmH2O): 5–(120 – PEEP)
  • PC above PEEP in NIV (cmH2 O): 5–(62 – PEEP)
  • CMV frequency (breaths/min): 4–100
  • I:E ratio: 1:10–4:1
  • TInsp (s): 0.1–5

Controlled Invasive Ventilation

  • PC (Pressure Control)
  • VC (Volume Control)
  • PRVC (Pressure Regulated Volume Control)
  • Can be configured with alternative flow patterns: VC with flow ada ptation; VC without flow adaptation; VC with decelerating flow

Supported Invasive Ventilation

  • PS/CPAP (Pressure Support / Continuous Positive Airway Pressure)

Combined Invasive Ventilation

  • SIMV (PC) + PS (Synchronized Intermittent Mandatory Ventilation)
  • SIMV (VC) + PS
  • SIMV (PRVC) + PS
  • Bi-Vent/APRV (Airway Pressure Release Ventilation)

Non Invasive Ventilation

  • Leakage Compensation Level: Inspiratory, up to 200 l/min; Expiratory, up to 65 l/ min
  • Leakage Overrange Detection: Automatic
  • Disconnect Detection: Automatic
  • Disconnect flow: Low; High; Disabled; Configurable 7.5 l/min; 40 l/min;
  • Deactivates disconnect detection
  • Connect Detection: Manual, or automatic via bias flow

Pre-owned, was removed from hospital in working condition.

International Shipping

We do our best to ship items the same day the payment has cleared, in some instances we are unable to. All items will be shipped within 1-4 working days

Returns

If you are not 100% satisfied with your purchase, we have a 14-day money back guarantee policy. Excluding Items sold as-is / for parts only. Reimbursement for returns will be paid after the purchased item is returned. Free returns apply to damaged, broken and items not as described! Buyer is responsible for return shipping on items purchased accidentally or items no longer wanted/needed etc.

We ship worldwide !

Please feel free to contact us for any question!


Sign in

Write us an email!

    Your name *

    Your email *

    Your message *

    We will call you back soon!

      Your name *

      Your phone number *

      Your email *

      Subject of the request *

      Contact us

      navigation-menu-horizontal navigation-menu-vertical navigation-menu remove-circle-alternate remove-circle-bold-alternate remove-circle