The MarketPlace auction starts in 7 days.
Ref: 1903260

PHOENIX Numo Ref. 1903260


9,188.00

BrandPHOENIX
ConditionNew
ModelNumo
Warranty24 month(s)

Microprocessor based with active exhalation valve
Suitable for Adult and Pediatric patients in ICU
7 inches of Screen Size
Modes Available
C-AC
VC-AC
PC-SIMV
VC-SIMV
PRVC
CPAP
PS
Battery backup of 2 hours
SETTING PARAMETERS
PIP – 0 to 60 cmH2O
Respiratory Rate – 1 to 60 BPM
Inspitatory time – 0.3 to 5 sec
Tidal volume – 50 to 2000 ml
Peak flow rate – 150 LPM
PEEP – 0 to 40 cmH2O
Pressure Support – 0 to 40 cmH2O
Inspiratory Pause
I : E ratio – 1 : 4 to 4 : 1
Flow Trigger – 1 to 10 LPM
Pressure Trigger – 1 to 20 LPM
Bias flow – 2 to5 LPM
Rise Profile – Low, Medium, High
FIO2 – 21% to 100% Electronic Blender
MONITORED PARAMETERS
Inhaled Tidal and Minute Volume
Exhaled Tidal and Minute Volume
Respiratory Rate
Total Leak volume %
Spontaneous Minute Volume
I : E ratio
Mean Pressure
Plateau Pressure
PEEP
Graphs: Flow Vs Time, Pressure Vs Time,
Volume Vs Time
ACCESSORIES
Ventilator stand – 1 no.
Patient circuit support arm – 1 no.
Patient circuit holder – 1 no.
Disposable Dual limb circuit with HME Filter and BV filter – 5 sets
Reusable exhalation value with flow sensor (fixed together) – 3 each
Test lung – 1 no.

price does not include shipping

5-7 days delivery


You are interested in this vehicle ?
Don’t wait any longer, get in touch with the company Health Tech Depot to know more right now !
9,188.00

Trusted Seller
Sold: 16770
Sold with Escrow: 3964
Registered: 22/09/2019
Shipping from: Spain
  Safety advice
BrandPHOENIX
ConditionNew
ModelNumo
Warranty24 month(s)

Microprocessor based with active exhalation valve
Suitable for Adult and Pediatric patients in ICU
7 inches of Screen Size
Modes Available
C-AC
VC-AC
PC-SIMV
VC-SIMV
PRVC
CPAP
PS
Battery backup of 2 hours
SETTING PARAMETERS
PIP – 0 to 60 cmH2O
Respiratory Rate – 1 to 60 BPM
Inspitatory time – 0.3 to 5 sec
Tidal volume – 50 to 2000 ml
Peak flow rate – 150 LPM
PEEP – 0 to 40 cmH2O
Pressure Support – 0 to 40 cmH2O
Inspiratory Pause
I : E ratio – 1 : 4 to 4 : 1
Flow Trigger – 1 to 10 LPM
Pressure Trigger – 1 to 20 LPM
Bias flow – 2 to5 LPM
Rise Profile – Low, Medium, High
FIO2 – 21% to 100% Electronic Blender
MONITORED PARAMETERS
Inhaled Tidal and Minute Volume
Exhaled Tidal and Minute Volume
Respiratory Rate
Total Leak volume %
Spontaneous Minute Volume
I : E ratio
Mean Pressure
Plateau Pressure
PEEP
Graphs: Flow Vs Time, Pressure Vs Time,
Volume Vs Time
ACCESSORIES
Ventilator stand – 1 no.
Patient circuit support arm – 1 no.
Patient circuit holder – 1 no.
Disposable Dual limb circuit with HME Filter and BV filter – 5 sets
Reusable exhalation value with flow sensor (fixed together) – 3 each
Test lung – 1 no.

price does not include shipping

5-7 days delivery


Sign in

navigation-menu-horizontal navigation-menu-vertical navigation-menu remove-circle-alternate remove-circle-bold-alternate remove-circle