The MarketPlace auction starts in 7 days.
Ref: 1953365

VALLEYLAB Force EZ Ref. 1953365


1,635.00

BrandVALLEYLAB
ConditionUsed Very Good
ModelForce EZ
WarrantyNot specified

Covidien Valleylab FORCE EZ-8

Electrosurgical generator

GOOD Working CONDITION

TESTED

FOOT SWITCH Included

FEATURES:

Instant response technology provides surgeons with improved performance or lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation, and decreasing the need to “turn up the generator.” The Force EZ generator adjusts automatically, responding to tissue changes, maintaining power delivery, and minimizing drag. Capacitive coupling is reduced by 30-50% when using Instant Response technology. This reduction is achieved by limiting the RMS voltage and the high-frequency harmonics. Lower voltage means less neuromuscular stimulation and a more precise delivery of energy to reduce collateral damage.

Instant Response technology features an advanced feedback system that recognizes changes in tissue 200 times per second and adjusts voltage and current accordingly to maintain appropriate power. This unique capability differentiates Instant Response generators by their high power efficiency rating (PER). That’s smart generator technology. PER indicates the ability of a generator to accurately deliver the selected power into a wide range of tissue types. With a PER of 97, the Force EZ generator provides a consistent surgical effect.

Instant Response technology ensures that the power delivered remains virtually constant, regardless of the tissue type

Improved performance at lower power settings minimizes the risk of tissue damage and neuromuscular stimulation

Three internal microcontrollers reduce system reaction time and increase the system’s processing speed

Easy to use, cost effective system when performance is required and price is of equal concern

Two cut modes, both controlled by Instant Response technology, offer surgeons a variety of choices:

Pure Cut for a clean, precise cut

Blend for cutting with hemostatsis

Two primary coag modes:

Low for lower voltage contact coagulation suitable in laparoscopic and delicate tissue work

High for efficient noncontact coagulation in most applications.

Output Waveforms:

Bipolar: 470 kHz sinusoid

Monopolar Cut:

Pure: 393 kHz sinusoid

Blend: 393 kHz bursts of sinusoid, recurring at 27 kHz intervals. 50% duty cycle envelope

Monopolar Coag:

Desiccation:

Low 1: 240 ± 40 kHz sinusoid recurring at 39 kHz. 8% duty cycle

Low 2: 393 kHz sinusoid

Low 3: 393 kHz sinusoid

Fulguration:

High 1: 470 ± 40 kHz damped sinusoidal bursts with a repetition frequency of 57 kHz

High 2: 470 ± 40 kHz damped sinusoidal bursts with a repetition frequency of 30 kHz

Output power changes by less than 15% or 5 watts, whichever is greater, as the line voltage varies from 90-135 volts (into a 300 ohm load)

Low Frequency Leakage (50-60 Hz):

Source current, patient leads, all outputs tied together

Normal polarity, intact chassis ground: < 10µA

Normal polarity, ground open: < 50µA

Reverse polarity, ground open: < 50µA

Sink current, 140V applied, all inputs: < 50µA

High Frequency Leakage:

Bipolar: Less than 60 mArms

Monopolar: Less than 150 mArms

Operating Parameters:

Ambient Temperature range: 10° to 40° C (50° to 104° F)

Relative humidity: 30% to 75%, non-condensing

atmospheric Pressure: 700 to 1060millibars

Warm-up Time: If you transported or stored the generator at temperatures outside the operating temperature range, allow one hour for the generator to reach room temperature before use.

International Shipping

We do our best to ship items the same day the payment has cleared, in some instances we are unable to. All items will be shipped within 1-4 working days

Returns

If you are not 100% satisfied with your purchase, we have a 14-day money back guarantee policy. Excluding Items sold as-is / for parts only. Reimbursement for returns will be paid after the purchased item is returned. Free returns apply to items not as described! Buyer is responsible for return shipping on items purchased accidentally or items no longer wanted/needed etc.

We ship worldwide !

Please feel free to contact us for any question!


You are interested in this vehicle ?
Don’t wait any longer, get in touch with the company East West Medical to know more right now !
1,635.00

Trusted Seller
Sold: 490
Sold with Escrow: 116
Registered: 01/01/1970
Shipping from: France
Rating: (0 verified reviews)
  Safety advice
BrandVALLEYLAB
ConditionUsed Very Good
ModelForce EZ
WarrantyNot specified

Covidien Valleylab FORCE EZ-8

Electrosurgical generator

GOOD Working CONDITION

TESTED

FOOT SWITCH Included

FEATURES:

Instant response technology provides surgeons with improved performance or lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation, and decreasing the need to “turn up the generator.” The Force EZ generator adjusts automatically, responding to tissue changes, maintaining power delivery, and minimizing drag. Capacitive coupling is reduced by 30-50% when using Instant Response technology. This reduction is achieved by limiting the RMS voltage and the high-frequency harmonics. Lower voltage means less neuromuscular stimulation and a more precise delivery of energy to reduce collateral damage.

Instant Response technology features an advanced feedback system that recognizes changes in tissue 200 times per second and adjusts voltage and current accordingly to maintain appropriate power. This unique capability differentiates Instant Response generators by their high power efficiency rating (PER). That’s smart generator technology. PER indicates the ability of a generator to accurately deliver the selected power into a wide range of tissue types. With a PER of 97, the Force EZ generator provides a consistent surgical effect.

Instant Response technology ensures that the power delivered remains virtually constant, regardless of the tissue type

Improved performance at lower power settings minimizes the risk of tissue damage and neuromuscular stimulation

Three internal microcontrollers reduce system reaction time and increase the system’s processing speed

Easy to use, cost effective system when performance is required and price is of equal concern

Two cut modes, both controlled by Instant Response technology, offer surgeons a variety of choices:

Pure Cut for a clean, precise cut

Blend for cutting with hemostatsis

Two primary coag modes:

Low for lower voltage contact coagulation suitable in laparoscopic and delicate tissue work

High for efficient noncontact coagulation in most applications.

Output Waveforms:

Bipolar: 470 kHz sinusoid

Monopolar Cut:

Pure: 393 kHz sinusoid

Blend: 393 kHz bursts of sinusoid, recurring at 27 kHz intervals. 50% duty cycle envelope

Monopolar Coag:

Desiccation:

Low 1: 240 ± 40 kHz sinusoid recurring at 39 kHz. 8% duty cycle

Low 2: 393 kHz sinusoid

Low 3: 393 kHz sinusoid

Fulguration:

High 1: 470 ± 40 kHz damped sinusoidal bursts with a repetition frequency of 57 kHz

High 2: 470 ± 40 kHz damped sinusoidal bursts with a repetition frequency of 30 kHz

Output power changes by less than 15% or 5 watts, whichever is greater, as the line voltage varies from 90-135 volts (into a 300 ohm load)

Low Frequency Leakage (50-60 Hz):

Source current, patient leads, all outputs tied together

Normal polarity, intact chassis ground: < 10µA

Normal polarity, ground open: < 50µA

Reverse polarity, ground open: < 50µA

Sink current, 140V applied, all inputs: < 50µA

High Frequency Leakage:

Bipolar: Less than 60 mArms

Monopolar: Less than 150 mArms

Operating Parameters:

Ambient Temperature range: 10° to 40° C (50° to 104° F)

Relative humidity: 30% to 75%, non-condensing

atmospheric Pressure: 700 to 1060millibars

Warm-up Time: If you transported or stored the generator at temperatures outside the operating temperature range, allow one hour for the generator to reach room temperature before use.

International Shipping

We do our best to ship items the same day the payment has cleared, in some instances we are unable to. All items will be shipped within 1-4 working days

Returns

If you are not 100% satisfied with your purchase, we have a 14-day money back guarantee policy. Excluding Items sold as-is / for parts only. Reimbursement for returns will be paid after the purchased item is returned. Free returns apply to items not as described! Buyer is responsible for return shipping on items purchased accidentally or items no longer wanted/needed etc.

We ship worldwide !

Please feel free to contact us for any question!


Sign in

navigation-menu-horizontal navigation-menu-vertical navigation-menu remove-circle-alternate remove-circle-bold-alternate remove-circle