1
Negotiate Terms with Seller
Discuss and agree upon the equipment's condition, configuration, and pricing with the seller before proceeding.
Brand | ZEISS |
Condition | Refurbished |
Model | Cirrus 500 |
Warranty | 12 month(s) |
Includes:
Cirrus 500 OCT
Windows 7
Table
12 months warranty
Optional: Premier Lens: Add $2,500
——————————————
Description
The Zeiss Cirrus 500 HD-OCT provides essential OCT capabilities with a broad range of clinical applications to comprehensive ophthalmic practices. The new OCT camera enables quick OCT fundus image refresh making patient alignment more efficient.
Main Features Cirrus 500
——————————————
NEW Macular Thickness OU Analysis
Ganglion Cell Analysis
Guided Progression Analysis (GPA™)
Macular Thickness and Change Analysis
Macular Thickness Normative Data
NEW PanoMap Analysis
Wide-field structural damage assessment for glaucoma
Zeiss PanoMap
Zeiss PanoMap
New PanoMap wide field analysis displays structural data for the entire posterior pole – RNFL, ONH and GCO metrics show the extend of structural damage.
At-a-glance insight — A single analysis for integrated insights into early pathologies
Backward-compatible –PanoMap uses existing Macular Cube and Optic Disc Cube scans to provide a wide-field view of the posterior pole without altering scan protocols.
NEW Anterior Segment Premier Module from Zeiss
The first retinal OCT with full anterior chamber imaging and measurements
ChamberView image – Chamberview provides an expansive 15.5 mm wide view of the entire anterior chamber with objective tools for measuring anterior segment ocular structures.
HD Cornea Scan – 9mm high-resolution scan, including versatile tools for measuring thickness of residual stromal bed, LASIK flap, and other corneal structures.
Pachymetry Map –9 mm pachymetry map highlights corneal irregularities and identifies thinnest point for refractive surgery screening.
NEW OCT Goniometry
A non-contact method to help identify patients at risk of angle closure glaucoma
Angle ScanWide Angle-to-Angle scan and HD Angle Scan — Provide exquisite detail of the iridocorneal angle and include measurement tools for Angle Opening Distance (AOD500/750) and Trabecular Iris Space Area (TISA 500/750) to quantify and track degree of angle closure
NEW Smart HD Scan Patterns
Targeted visualizations of critical anatomy.
Automatic centering of scans ensures you see the fovea in each patient.
Cirrus Smart HD Scan Patters
Technical Specifications Cirrus 500
OCT Imaging
Methodology Spectral Domain OCT
Optical source Superluminescent diode (SLD), 840 nm
Scan speed 27,000 – 68,000 A-scans per second
A-scan depth 2.0 mm (in tissue), 1024 points
Axial resolution 5 µm (in tissue)
Transverse resolution 15 µm (in tissue)
Fundus Imaging
Methodology Line OCT Fundus
Live fundus image During alignment
Optical source Superluminescent diode (SLD), 840 nm
Field of view 36 degrees W x 30 degrees H
Frame rate > 1.7 Hz
Transverse resolution 45 µm (in tissue)
Iris Imaging
Methodology CCD camera
Resolution 1280 x 1024
Live iris image During alignment
Electrical and Physical
Weight 80 lbs (36 kg)
Dimensions of instrument 26L x 18W x 21H (in)
65L x 46W x 53H (cm)
Dimensions of table 39L x 22W (in)
99L x 56W (cm)
Fixation Internal, external
Internal fixation focus adjustment -20D to +20D (diopters)
Electrical rating (115V) Single Phase, 100–120V~ systems: 50/60Hz, 5A
Electrical rating (230V) Single Phase, 220–240V~ systems: 50/60Hz, 2.5A
Internal Computer
Operating system/processor Windows ® 7, 4 th generation i7 Intel ® processor
Memory 16 GB
Hard drive/internal storage ≥ 2 T
> 200,000 scans
Display Integrated 19“ color flat panel display
USB ports 6 ports
Return Policy
Returns All equipment sales are FINAL, no item can be returned without approval by returns department and must contain RMA #. If an item is approved for a return it will be assessed a 20% restocking fee, unless it’s due to factory defect and then fee will not be assessed. Factory evaluation is necessary prior to fee being waived. Buyer has 3 working days from receipt of equipment for claims of shortage or damage of any kind. Claims must be made in writing and in the event of damage; buyer must retain any and all packaging with the equipment for inspection. Failure to retain the packaging will void your rights to relief occurring as a result of transport damages. No returns are allowed after 15 (fifteen) days of receiving the order for any reason. Special orders, custom fabrication and similar service are non-refundable and non-returnable for any reason. All returns if approved must be returned to us prepaid and in good conditions. Any deficiencies in the return item due to normal wear, neglect, abuse, shipping damages, etc. are the responsibility of the buyer and deductions for repair will be assessed. The Buyer authorizes Digital Eye Center. to charge the purchaser’s credit card for restocking fees, travel expenses and any other assessed charges from deficiencies as set forth in this paragraph. All approved refunds will be charged back to the same method of payment within 10 business days after approved the refund. All equipment unless otherwise noted are FOB Miami, FL Unless otherwise noted payment is due at time of placement of order. Costs for overdue accounts sent for collections and/or enforcement of the terms of sale, including legal collection service etc. are the responsibility of the buyer and governing law for all transactions with Digital Eye Center will be construed and interpreted in the state of Florida.
Brand | ZEISS |
Condition | Refurbished |
Model | Cirrus 500 |
Warranty | 12 month(s) |
Includes:
Cirrus 500 OCT
Windows 7
Table
12 months warranty
Optional: Premier Lens: Add $2,500
——————————————
Description
The Zeiss Cirrus 500 HD-OCT provides essential OCT capabilities with a broad range of clinical applications to comprehensive ophthalmic practices. The new OCT camera enables quick OCT fundus image refresh making patient alignment more efficient.
Main Features Cirrus 500
——————————————
NEW Macular Thickness OU Analysis
Ganglion Cell Analysis
Guided Progression Analysis (GPA™)
Macular Thickness and Change Analysis
Macular Thickness Normative Data
NEW PanoMap Analysis
Wide-field structural damage assessment for glaucoma
Zeiss PanoMap
Zeiss PanoMap
New PanoMap wide field analysis displays structural data for the entire posterior pole – RNFL, ONH and GCO metrics show the extend of structural damage.
At-a-glance insight — A single analysis for integrated insights into early pathologies
Backward-compatible –PanoMap uses existing Macular Cube and Optic Disc Cube scans to provide a wide-field view of the posterior pole without altering scan protocols.
NEW Anterior Segment Premier Module from Zeiss
The first retinal OCT with full anterior chamber imaging and measurements
ChamberView image – Chamberview provides an expansive 15.5 mm wide view of the entire anterior chamber with objective tools for measuring anterior segment ocular structures.
HD Cornea Scan – 9mm high-resolution scan, including versatile tools for measuring thickness of residual stromal bed, LASIK flap, and other corneal structures.
Pachymetry Map –9 mm pachymetry map highlights corneal irregularities and identifies thinnest point for refractive surgery screening.
NEW OCT Goniometry
A non-contact method to help identify patients at risk of angle closure glaucoma
Angle ScanWide Angle-to-Angle scan and HD Angle Scan — Provide exquisite detail of the iridocorneal angle and include measurement tools for Angle Opening Distance (AOD500/750) and Trabecular Iris Space Area (TISA 500/750) to quantify and track degree of angle closure
NEW Smart HD Scan Patterns
Targeted visualizations of critical anatomy.
Automatic centering of scans ensures you see the fovea in each patient.
Cirrus Smart HD Scan Patters
Technical Specifications Cirrus 500
OCT Imaging
Methodology Spectral Domain OCT
Optical source Superluminescent diode (SLD), 840 nm
Scan speed 27,000 – 68,000 A-scans per second
A-scan depth 2.0 mm (in tissue), 1024 points
Axial resolution 5 µm (in tissue)
Transverse resolution 15 µm (in tissue)
Fundus Imaging
Methodology Line OCT Fundus
Live fundus image During alignment
Optical source Superluminescent diode (SLD), 840 nm
Field of view 36 degrees W x 30 degrees H
Frame rate > 1.7 Hz
Transverse resolution 45 µm (in tissue)
Iris Imaging
Methodology CCD camera
Resolution 1280 x 1024
Live iris image During alignment
Electrical and Physical
Weight 80 lbs (36 kg)
Dimensions of instrument 26L x 18W x 21H (in)
65L x 46W x 53H (cm)
Dimensions of table 39L x 22W (in)
99L x 56W (cm)
Fixation Internal, external
Internal fixation focus adjustment -20D to +20D (diopters)
Electrical rating (115V) Single Phase, 100–120V~ systems: 50/60Hz, 5A
Electrical rating (230V) Single Phase, 220–240V~ systems: 50/60Hz, 2.5A
Internal Computer
Operating system/processor Windows ® 7, 4 th generation i7 Intel ® processor
Memory 16 GB
Hard drive/internal storage ≥ 2 T
> 200,000 scans
Display Integrated 19“ color flat panel display
USB ports 6 ports
Return Policy
Returns All equipment sales are FINAL, no item can be returned without approval by returns department and must contain RMA #. If an item is approved for a return it will be assessed a 20% restocking fee, unless it’s due to factory defect and then fee will not be assessed. Factory evaluation is necessary prior to fee being waived. Buyer has 3 working days from receipt of equipment for claims of shortage or damage of any kind. Claims must be made in writing and in the event of damage; buyer must retain any and all packaging with the equipment for inspection. Failure to retain the packaging will void your rights to relief occurring as a result of transport damages. No returns are allowed after 15 (fifteen) days of receiving the order for any reason. Special orders, custom fabrication and similar service are non-refundable and non-returnable for any reason. All returns if approved must be returned to us prepaid and in good conditions. Any deficiencies in the return item due to normal wear, neglect, abuse, shipping damages, etc. are the responsibility of the buyer and deductions for repair will be assessed. The Buyer authorizes Digital Eye Center. to charge the purchaser’s credit card for restocking fees, travel expenses and any other assessed charges from deficiencies as set forth in this paragraph. All approved refunds will be charged back to the same method of payment within 10 business days after approved the refund. All equipment unless otherwise noted are FOB Miami, FL Unless otherwise noted payment is due at time of placement of order. Costs for overdue accounts sent for collections and/or enforcement of the terms of sale, including legal collection service etc. are the responsibility of the buyer and governing law for all transactions with Digital Eye Center will be construed and interpreted in the state of Florida.