1
Negotiate Terms with Seller
Discuss and agree upon the equipment's condition, configuration, and pricing with the seller before proceeding.
Brand | ZEISS |
Condition | Refurbished |
Model | IOL Master 500 |
Warranty | 6 month(s) |
Measurement range
Axial length 14 – 38mm
Corneal radii 5 – 10mm
Anterior chamber depth 1.5 – 6.5mm
White-to-white 8 – 16mm
Display scaling
Axial length 0.01mm
Corneal radii 0.01mm
Anterior chamber depth 0.01mm
White-to-white 0.1mm
IOL calculation formulas
Haigis, Hoffer® Q, Holladay 1 and 2, SRK® II, SRK® / T
Clinical history and contact lens fitting method for calculation of corneal refractive power following refractive corneal surgery
Haigis-L IOL calculation for eyes following
myopic/ hyperopic LASIK / PRK /LASEK surgery
Calculation of phakic anterior and posterior chamber implants
Optimization of IOL constants
Interfaces
Ultrasound data link
ZEISS eyecare data management system FORUM®
ZEISS computer-assisted cataract surgery system CALLISTO eye (via USB)
Data interface for electronic medical record (EMR) / patient management systems (PMS)
Data export to USB storage media
Export database for Holladay IOL Consultant and HIC.SOAP Pro
Ethernet port for network connection and network printer
Line voltage
100 – 240 V ± 10% (self sensing)
Line frequency 50 – 60 Hz
Product Details
Warranty
6 months
In stock 1 Item
Condition Refurbished
Brand | ZEISS |
Condition | Refurbished |
Model | IOL Master 500 |
Warranty | 6 month(s) |
Measurement range
Axial length 14 – 38mm
Corneal radii 5 – 10mm
Anterior chamber depth 1.5 – 6.5mm
White-to-white 8 – 16mm
Display scaling
Axial length 0.01mm
Corneal radii 0.01mm
Anterior chamber depth 0.01mm
White-to-white 0.1mm
IOL calculation formulas
Haigis, Hoffer® Q, Holladay 1 and 2, SRK® II, SRK® / T
Clinical history and contact lens fitting method for calculation of corneal refractive power following refractive corneal surgery
Haigis-L IOL calculation for eyes following
myopic/ hyperopic LASIK / PRK /LASEK surgery
Calculation of phakic anterior and posterior chamber implants
Optimization of IOL constants
Interfaces
Ultrasound data link
ZEISS eyecare data management system FORUM®
ZEISS computer-assisted cataract surgery system CALLISTO eye (via USB)
Data interface for electronic medical record (EMR) / patient management systems (PMS)
Data export to USB storage media
Export database for Holladay IOL Consultant and HIC.SOAP Pro
Ethernet port for network connection and network printer
Line voltage
100 – 240 V ± 10% (self sensing)
Line frequency 50 – 60 Hz
Product Details
Warranty
6 months
In stock 1 Item
Condition Refurbished