1
Negotiate Terms with Seller
Discuss and agree upon the equipment's condition, configuration, and pricing with the seller before proceeding.
Brand | ZOLL |
Condition | Certified Refurbished |
Model | M Series |
Warranty | Not specified |
Manual or AED defibrillation modes.
Delivers up to 360 joules into a 50-ohm impedance.
ECG Monitoring with 3 or 5 lead patient cable.
Up to 2.5 hours of monitoring on battery power.
Integrated CPR assistance.
M Series Specifications
Dimensions
Height: 6.8 in (17.3 cm)
Width: 10.3 in (26.2 cm)
Depth: 8.2 in (20.8 cm)
Weight: 11.5 lbs (5.23 kg)
Battery
Type: Sealed lead acid
Cells: 5
Operating Time: About 2.5 hours
Charging Time: About 7.2 hours
Display
Screen Type: High-resolution Liquid crystal display (LCD)
Size: 5.66 inches (14.4 cm) diagonally
Sweep Speed: 25 mm/sec, 50 mm/sec (Configurable for 12-lead ECG recording)
Viewing Time: 4 seconds
Power
AC Power: 100-120 ~ 50/60 Hz, 220-240 ~ 50 Hz, 220 VA
DC Input: 10-29 V. 130 W
ECG Monitoring
Patient Connection: 3 or 5-lead ECG cable, paddles, or MFE pads
Heart Rate Range: 30 to 300 bpm
Heart Rate Accuracy: ±5%
Response time to Change in Heart Rate: 80 to 120 bpm: 4 Seconds; 80 to 40 bpm: 4.25 seconds
CPR Monitoring
Compression Depth: 0.75 to 3 inches ±0.25 inches (1.9 to 7.6 cm ±0.6 cm)/li>
Compression Rate: 50 to 150 compressions per minute
Recorder
Paper: 80 mm thermal (grid width), 90 mm (paper width)
Speed: 25 mm/sec
Delay: 6 seconds
Method: Thermal-array printhead
PCMCIA Card
Capacity: Standard series II flashcard – 1 megabyte to 16 megabytes
Audio Recording: Digital compressed audio data
Brand | ZOLL |
Condition | Certified Refurbished |
Model | M Series |
Warranty | Not specified |
Manual or AED defibrillation modes.
Delivers up to 360 joules into a 50-ohm impedance.
ECG Monitoring with 3 or 5 lead patient cable.
Up to 2.5 hours of monitoring on battery power.
Integrated CPR assistance.
M Series Specifications
Dimensions
Height: 6.8 in (17.3 cm)
Width: 10.3 in (26.2 cm)
Depth: 8.2 in (20.8 cm)
Weight: 11.5 lbs (5.23 kg)
Battery
Type: Sealed lead acid
Cells: 5
Operating Time: About 2.5 hours
Charging Time: About 7.2 hours
Display
Screen Type: High-resolution Liquid crystal display (LCD)
Size: 5.66 inches (14.4 cm) diagonally
Sweep Speed: 25 mm/sec, 50 mm/sec (Configurable for 12-lead ECG recording)
Viewing Time: 4 seconds
Power
AC Power: 100-120 ~ 50/60 Hz, 220-240 ~ 50 Hz, 220 VA
DC Input: 10-29 V. 130 W
ECG Monitoring
Patient Connection: 3 or 5-lead ECG cable, paddles, or MFE pads
Heart Rate Range: 30 to 300 bpm
Heart Rate Accuracy: ±5%
Response time to Change in Heart Rate: 80 to 120 bpm: 4 Seconds; 80 to 40 bpm: 4.25 seconds
CPR Monitoring
Compression Depth: 0.75 to 3 inches ±0.25 inches (1.9 to 7.6 cm ±0.6 cm)/li>
Compression Rate: 50 to 150 compressions per minute
Recorder
Paper: 80 mm thermal (grid width), 90 mm (paper width)
Speed: 25 mm/sec
Delay: 6 seconds
Method: Thermal-array printhead
PCMCIA Card
Capacity: Standard series II flashcard – 1 megabyte to 16 megabytes
Audio Recording: Digital compressed audio data